Thermon PCA-COM Bedienungsanleitung Seite 3

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 8
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 2
2
1.2. Slide expediter toward pipe and secure
cap to base with the captive screws.
1.3. Mount expediter to pipe using two (2)
circumferential bands of 19mm (3/4”)
wide tape.
1.4. Place UL
®
label provided as shown,
locate on opposite side from rectangular
side opening.
Pipe Heating Cable 134N
HSX
®
or FLX Heating Cable System
Install Cable per NEC Article 427
Thermon Manufacturing Co.
100 Thermon Dr., San Marcos, Texas 78666
1-800-730-4328 PN 27400
1.5. Cutandremoveheatingcableoverjacket.
Do not cut bus metallic braid.
1.6. Separate braid strands at edge of
overjacketandpullcablethroughopening.
1.7. Twist braid into a pigtail. Trim ends of braid.
1.1b. Two cables.
1.1c. Three cables.
PCA-COM
152mm
(6”)
Braid
Power connection for FLX -OJ cables and HSX cables. For cables with braid only, skip to Step 3.1 on page 4.
Tape Provided
Separately
UL Label
1.1a. For one, two or three cables. Insert cable
into expediter, grommet, and NPT
threaded cap.
Seitenansicht 2
1 2 3 4 5 6 7 8

Kommentare zu diesen Handbüchern

Keine Kommentare